Frequently Asked Questions

Home FAQs

Information Questions

Our FAQs are separated categorically for your convenience. Please browse the following sections at your leisure. If you have a question that isn’t answered here or elsewhere on our site, let us know!

Wheel service

Our PULI Products division has dozens of wheel service equipment options. We’ll continue to update this section with answers to common questions about operating the equipment, wiring/electrical information and other need-to-know facts about our extensive suite of wheel service equipment.

Car Lift

When a vehicle is in the air, and an operator is underneath the auto lift, following all proper safety procedures could not be more important. So, we want to answer any question you may have, big or small. Review your owner’s manual and consult these FAQs if you have questions.

Shop equipment

Every piece of shop equipment we offer is unique, so we’d like to help you navigate some of the common questions and concerns you may have. We might not be able to cover everything, but if you don’t see something here, let us know and we’ll add it to the list.

Support

Questions about what happens after you order a car lift? Need information about missing/replacement parts? Look here first, so you know what to expect .

General Questions

Our FAQs are separated categorically for your convenience. Please browse the following sections at your leisure. If you have a question that isn’t answered here or elsewhere on our site, let us know!

The existing tyre changer motor is 220V, how to operate if we want to replace it with 380V motor?

We need to replace the 220V motor with 380V motor, also the power cord(line) needs to be replaced. The connection of the switch needs to be adjusted, then the connection can be made according to the correct connection method.

Why appears the phenomenon that the bead breaker blade presses tyre weakly?

Firstly, check whether the working pressure of the machine reaches 8-10bar. If it doesn’t reach enough pressure numerical value, the bead breaker blade will press tyre weakly. If the pressure is sufficient, check if there is air leakage in the bead breaker cylinder

What about the noise when the machine is running?

Firstly, we need to find out where the noise comes from. Generally, there will be motor noise and gear box noise. Then, check it if there is still noise when running the motor without belt, it is the noise of the motor itself. Otherwise, it is the gear box noise.

How to adjust it when appear the phenomenon that the demounting head scratches the rim during we are removing the tyre.

Firstly, we should adjust the angle of the demounting head to align the middle line of the demounting tail with the rim edge. If the angle of the demounting head is appropriate, observe whether there is a large shape variable on the column or hex bar when the tyre is under pressure. If there is, we should replace the corresponding parts.

What's kind of oil in the oil cup of oil distributor?

They are # 20 machine oil, air gun oil, sewing machine oil, transformer oil, etc.

How to adjust the working pressure of the machine?

Lift the button of the pressure regulating valve on the air regulator assembly up, then turn clockwise to increase the pressure or turn counterclockwise to decrease the pressure, and press the knob down to lock after adjusting to the standard operating pressure.

If the pedal cannot return to its position after stepping the pedal, why(what's the reason)?

Generally, there will be something wrong in the return spring or spring plate on the pedal assembly. We can disassemble the pedal front face to see if there is any damage in the accessory and replace it to solve the problem.

Is it feasible if we want to operate 24 inch tires with the existing 885A series machine?

It is recommended to upgrade to a 22-inch inner adjustable round turntable with three position adjustable and a clamping range of 9-26 inches.

Information Tire Changer Questions

Our FAQs are separated categorically for your convenience. Please browse the following sections at your leisure. If you have a question that isn’t answered here or elsewhere on our site, let us know!

Are there measures to protect the rim from being scratched by clamping claws?

The jaw protector cover can be installed on the jaw to protect the rim.

The bead breaker blade pressing tyres will scratch the rim, is there a good protection method?

We can install the protective cover on the bead breaker blade to effectively protect the rim from scratches when pressing tyres.

Is there any change in the size of the tyre remover after the tyre changer is equipped with motorcycle adapter?

If the tyre changer is equipped with motorcycle adapter, it can reduce 2 inches or increase 3 inches on the basis of the normal external clamping range. For example, the normal external clamping range is 10-20 inches, if the tyre changer is equipped with motorcycle adapter, the clamping range is 8-23 inches.

How to connect the motor when replacing the 220V motor?

Power lines connect with1,3; Motor lines: Z1 connects with 7, Z2 connects with 11, U1connects with 8, U2connects with2

How to connect the motor when replacing the 380V motor?

Power lines connect with 1,5,9;Motor lines connect with 2,6,8.

If we want to improve the operating speed, is it feasible to replace the motor with a double-speed motor?

The plan is feasible. However, some models are limited by the size of the box and cannot replace the double-speed motor.

The tyre is not clamped tightly on the turntable and skidded when it is demounting and loaded.

Firstly, check the appearance of the clamping claw. If the tip on the back of the clamping claw is badly worn, the tyre will not be hold up tightly. In addition, small cylinder channeling or air leakage will also cause support clamping.
NEED HELP?
Choosing Right Product,Price Guarantee,Customized Solution,Training & Technical Services
Email: export-unite#balancer-sh.com
Looking For Exclusive Service?
Since 1980s as a manufacturer of tyre changers, lifting equipment, wheel balancers, wheel-alignment and testing equipment.